Home / Science / Molecular and cell biology / Cell biology and cell culture / Transfection and plate layout plannerTool #190

Transfection planner: plate layout (6 to 384 wells), DNA, reagent and master mix volumes

Lay out your constructs, controls and replicates on a 6 to 384-well plate, automatically or by tapping wells. Get the DNA, reagent, diluent and medium for every tube and well from your amounts per well, with a spare margin, a printable colour plate map and a pipetting table.

Keep it one tap away for everyday use.

Bookmark Transfection and plate layout planner?

Press Ctrl + D now. Your browser opens its own bookmark box, where you choose the name and folder.

  1. Plate
  2. Conditions
  3. Map
  4. Pipette
Nothing is uploadedWorks offline once open

Plate and amounts per well

The starting amounts are rounded values made up by fibub that grow with the well size. They are not from any kit: type the amounts your reagent's instructions give. Reagent per µg DNA sets the reagent : DNA ratio. The diluent (often serum-free medium) is split between the DNA tube and the reagent tube. Spare makes a little extra of every mix so the last well is not short.

Conditions

A construct or control plasmid gets DNA and reagent. Mock gets reagent and diluent but no DNA, to show what the reagent alone does. Untransfected wells only get medium. The DNA stock is used to work out how many µL of DNA to pipette.

Plate map

Auto layout puts each condition's replicates next to each other in fill order. Tap a well to put the chosen condition there; tap it again to empty it. Once you change the map by hand, the replicates come from the map, until you press Auto layout.

Pipetting plan

    Plate map and plan

    What it does

    A transfection is easy to describe and fiddly to set up: six constructs in triplicate, a mock, an untransfected control, a plate that has to be mapped, and a pile of small volumes that all scale with the number of wells. This planner does the layout and the sums together. Pick a plate, list your conditions with their replicates, and you get a colour plate map you can print, one reagent master mix for everything, and a table that says exactly what goes in each tube.

    It works for lipid and polymer reagents that are mixed with DNA in a diluent (often serum-free medium) and then added to cells. It does not hold any kit’s numbers: the starting amounts are rounded values made up by fibub, so type in what your reagent’s instructions say.

    How to use it

    1. Plate and amounts per well. Choose 6, 12, 24, 48, 96 or 384 wells. The amounts change to rounded starting values for that size. Then set:
      • DNA per well (ng): how much plasmid each well gets.
      • Reagent per µg DNA (µL): the reagent : DNA ratio. 3 means 3 µL of reagent for every µg of DNA.
      • Diluent per well (µL) and Diluent in the DNA tube (%): the diluent is split between a DNA tube and a reagent tube, which are combined later. 50 % puts half in each. 100 % means the reagent goes in neat.
      • Medium per well (µL): the medium already on the cells.
      • Spare (%): extra in every tube so the last well is not short.
    2. Conditions. Give each one a name, a type and replicates. A construct or control plasmid gets DNA and reagent and needs its stock in ng/µL. Mock gets the reagent and diluent but no DNA. Untransfected wells only get medium.
    3. Plate map. Auto layout puts each condition’s replicates side by side, across rows or down columns, and can keep the edge wells empty. To change it by hand, choose a condition in “Tapping a well puts” and tap wells; tap a well again to empty it. The amounts always follow the map.
    4. Pipetting plan. Follow the steps: make the reagent mix, fill one DNA tube per condition, add the reagent mix to each tube, then add the complex to each well. Download the plan as an image, PDF or Word file, or the table and the well list as CSV.

    The maths

    For every well with reagent: reagent = ratio × DNA (in µg). The DNA tube holds diluent × share, the reagent tube diluent × (1 − share) + reagent, and the complex per well is both together. A condition with n wells is made for n × (1 + spare). Its DNA volume is the DNA mass ÷ the stock, and diluent tops the DNA tube up to its volume. The shared reagent mix is made for everything the tubes take from it, plus the spare once more, since it is pipetted again.

    Worked example

    The page opens with a made-up 24-well plan: Gene X (500 ng/µL), Gene X mutant (400 ng/µL), an empty vector (1000 ng/µL), GFP (200 ng/µL), a mock and an untransfected control, each in triplicate, with 500 ng DNA, 3 µL reagent per µg, 50 µL diluent split half and half, 500 µL medium and 10 % spare. That is 18 wells, rows A to C.

    Each well gets 1.50 µL of reagent and 51.5 µL of complex. Gene X is made for 3.30 wells: 1.65 µg of DNA, which is 3.30 µL of stock, plus 79.2 µL of diluent, then 87.5 µL of reagent mix. The mutant needs 4.13 µL of DNA and GFP 8.25 µL. Five tubes take reagent mix, so the mix is 481 µL: 27.2 µL of reagent in 454 µL of diluent. The medium for 18 wells with spare is 9.90 mL.

    Tips

    • Keep the reagent : DNA ratio the same across conditions, and change only the DNA, so the mock is a fair control.
    • If a DNA volume is below about 0.5 µL, dilute the stock first; the page warns you.
    • The complex is usually a small part of the well; the page warns when it is more than a quarter of the medium.
    • For a co-transfection, premix the plasmids and enter the mix as one construct with its combined concentration.

    FAQ

    Why is there spare twice? Each tube is made for its wells plus spare, and the reagent mix is made for all the tubes plus spare again, since every transfer loses a little.

    Can I mix plate sizes? Plan each plate separately.

    Is anything saved or sent? No. Everything runs in your browser and is gone when you close the page.

    Where the numbers come from

    • The arithmetic (amount per well × wells × spare, DNA volume = mass ÷ stock, reagent = ratio × DNA) is written by fibub and checked in the tests against a hand-worked example and an independent NumPy script.
    • The starting amounts per well and the example stocks are rounded values made up by fibub. They are not from any kit insert or paper; type the amounts your reagent's instructions give.

    Standard scientific values, such as constants, atomic weights and melting points, are facts found in every textbook; we name where ours were checked. If you are an author or publisher and want a value, a credit or a table changed or removed, tell us and we will act quickly.

    Last updated 2026-11-09.

    Change log for Transfection and plate layout planner

    1. Add #190 Transfection and plate layout planner Details on GitHub

    Every change to fibub

    Related tools

    MOI calculator #199 Work out the MOI from your cell number and virus titre (PFU, TCID₅₀ or transducing units), or the volume of virus to add for a target MOI. See how many cells get 0, 1, 2 or more particles, the MOI needed for a target % infected, and a plate plan with predilutions for several MOIs. Everything stays in your browser. Hemocytometer cell counter #36 Tally live and dead cells square by square with on-screen buttons or the keyboard. Get cells per mL, viability, the counting error, and exactly how much suspension and medium to mix to seed your plates. PCR master mix calculator #31 Type your stocks and final concentrations, the reaction volume and the number of reactions. Get the volume of every component for one reaction and for the whole mix with spare, plus water, as a tick-off list. Plate layout designer #35 Lay out standards, samples, controls and blanks with replicates on any plate from 6 to 1536 wells. Keep the edge wells empty, then print the map or export a well list for your plate reader or liquid handler. Cell doubling time and passage planner #189 Type two or more cell counts and get the doubling time from a log-linear fit, with the growth rate, generations and a 95 % interval. Then plan the next passage: how many cells to seed per flask or well to reach a target confluence on the day you want, the split ratio, the volume to pipette and a schedule of the next passages. Fluorescence image analyser #191 Open a fluorescence microscope image, pick the channel, take away the background, set a threshold and split touching nuclei. Get the count, each object's area, mean and integrated intensity, a histogram, an outlined and numbered overlay, a CSV and a report. The image stays in your browser.