What it does
Most oscilloscopes can save what is on the screen as a CSV file: a time column and one column per channel, often with a few lines of settings at the top. This viewer opens that file in your browser, plots every channel, and makes the standard automatic measurements a scope makes, so you can measure saved captures later, check the scope’s own numbers, or put clean figures and tables into a lab report.
How to use it
- Open the CSV (or paste it). Lines of settings such as “Record Length” and the column titles are found and skipped automatically. If the file has no time column, type the sample interval in seconds.
- Choose the channel to measure and, for the phase, the channel to compare it with.
- Choose the rise and fall levels (10 to 90 % is the usual definition, 20 to 80 % suits slow or ringing edges) and the hysteresis, which stops noise near a level from counting as extra edges.
- To measure only part of the capture, give a from and to time.
- Read the measurement table (every channel side by side), the phase line, the plot with the 10, 50 and 90 % levels, and the zoom on the first rising edge. Download the table as CSV or the report as an image, PDF or Word file.
How the measurements are made
- Top and base are the most common high and low values (the IEEE 181 histogram method), so overshoot and noise do not move them; for a sine wave with no flat parts they are the peaks. The amplitude is top minus base.
- Frequency and period come from the times the signal rises through 50 % of the amplitude, interpolated between samples and averaged over all whole cycles in view.
- Rise time runs from the low to the high level on each rising edge, averaged over all edges; fall time likewise. The duty cycle is the time above 50 % divided by the period.
- Phase is given two ways: from the fundamental (a Fourier component over a whole number of periods, best for sine-like signals) and from the delay between 50 % rising edges (what you would read off the screen). Positive means the second channel lags.
Worked example
The example is a simulated capture: CH1 is a 1 kHz, 3.3 V logic signal after an RC filter with a 10 µs time constant, CH2 a 1 V sine wave 45° behind the logic signal, 4,000 samples 1 µs apart. The page measures CH1 at 999.99 Hz with a rise time of 21.9 µs (theory: τ ln 9 = 22.0 µs), fall time 21.8 µs and a 50 % duty cycle. CH2 has an AC RMS of 707.1 mV (1 V ÷ √2). The phase line reads CH2 lags CH1 by 41.39° at the fundamental (45° minus the RC filter’s own lag of 3.6°) and the delay between edges is 118.2 µs, or 42.53°. With 20 to 80 % levels the rise time is 13.8 µs (τ ln 4).
FAQ
My scope saves in another format. Any CSV, TSV, text or Excel file with a time column and channel columns works. Binary formats need the scope’s own software to convert them first.
Is my data uploaded? No. The file is read and measured in this page only.
Where the numbers come from
- Pulse and transition terms and the histogram method for top and base levels: IEEE Std 181-2011 (IEEE Standard for Transitions, Pulses, and Related Waveforms), used for definitions only. Rise time of an RC circuit τ ln 9 and its phase lag atan(ωτ): standard circuit theory.
- Checked against theory on noise-free traces and against an independent numpy implementation on the noisy example, written for the tests.
- The example capture is simulated (made up).