Greenhouse heating and ventilation calculator: heat loss, heater size, fuel use, air changes and fans

Work out a greenhouse's heat loss through the cover and air leaks, the heater size you need, the fuel it will burn over a season, and the ventilation needed to keep it cool in full sun: air flow, air changes per minute and number of fans. Nothing is uploaded.

Keep it one tap away for everyday use.

Bookmark Greenhouse heating and ventilation calculator?

Press Ctrl + D now. Your browser opens its own bookmark box, where you choose the name and folder.

  1. Size
  2. Cover
  3. Heater
  4. Fans
Nothing is uploadedWorks offline once open

Greenhouse

A single-span greenhouse with a pitched (gable) roof; for a flat roof make the ridge height equal to the eave height. U values in the list are rounded examples: use your supplier's figure if you have it. Altitude sets the air pressure, which changes how much heat air carries.

Heating

Air changes per hour: how often leaks replace the air. A tight double-film house may be about 0.5; an older glasshouse 1 to 2 or more. The coldest outside temperature is the one you design for, not the record low.

Fuel over a season

Degree-days add up how far, and for how long, the outside stays below your set point over the season; your weather service publishes them for your base temperature. Energy contents in the list are rounded examples; check your supplier's figure.

Ventilation

Full summer sun is about 800 to 1000 W/m². A full, well-watered crop uses about half the sunlight to evaporate water (which cools without warming the air); use 0 for an empty house. The fan figure is at the pressure it works against: take it from the fan's data sheet.

Download

What it does

A greenhouse loses heat in two ways: through the cover (glass or plastic) and through air leaking in and out. In summer it has the opposite problem: sunlight heats the air, and fans or vents must swap it for cooler outside air. This calculator does both sums from physics, not from rule-of-thumb tables.

Heating. Heat loss = U × cover area × (inside − outside temperature) + air density × heat capacity × volume × air changes per hour ÷ 3600 × (inside − outside). U is how many watts pass through a square metre of cover for each degree of difference. The page gives the heat loss, the share through the cover and through leaks, and the heater size with your safety margin, in kW and BTU/h.

Fuel over a season. Heating degree-days add up how far the outside stays below your set point, day by day. Multiply by 24 hours and by the greenhouse’s heat loss per degree, divide by the fuel’s energy content and the heater’s efficiency, and you have the season’s fuel use and, with a price, its cost.

Ventilation. The sunlight that gets through the cover, minus the share the crop uses to evaporate water, warms the air. To keep the inside only a few degrees above outside, that heat must leave with outside air: flow = heat ÷ (air density × heat capacity × allowed rise). You get the flow in m³/s, m³/h and CFM, the air changes per minute, and the number of fans.

How to use it

  1. Enter the greenhouse size and pick the cover. The listed U values are rounded examples; type your own if you know it.
  2. Enter the inside set point, the coldest outside temperature you design for, how leaky the house is (air changes per hour) and a safety margin.
  3. For the season, enter heating degree-days for your site and set point, the fuel, and optionally its price.
  4. For ventilation, enter the strongest sunlight, how much the cover lets through, how much the crop uses, the outside temperature and the rise you will accept, and your fan’s rated flow.

Worked example

Press Use the example: a made-up house 30 m long, 9.6 m wide, 3 m to the eaves and 4.8 m to the ridge, covered with double inflated film (example U = 4.0). It has 288 m² of floor, 562.5 m² of cover and 1,123.2 m³ of air.

Holding 18 °C when it is −10 °C outside with one air change an hour, it loses 74.8 kW: 63.0 kW (84 %) through the cover and 11.8 kW (16 %) through leaks. With a 10 % margin the heater should be 82.3 kW, about 280,694 BTU/h, or 260 W per m² of floor. Over a season of 3,000 degree-days that is 192,303 kWh of heat, or 21,433 m³ of natural gas at an example 38 MJ/m³ and 85 % efficiency.

In summer sun of 800 W/m², with 70 % getting through and half used by the crop, 80.6 kW warms the air, and 9.0 kW leaves through the cover at a 4 °C rise. Holding the rise to 4 °C with 28 °C outside needs 15.19 m³/s, which is 0.81 air changes a minute, or 2 fans of 35,000 m³/h.

FAQ

Why does the ventilation fall so fast as I allow a bigger rise? The flow is divided by the allowed rise: halving the rise doubles the air you must move.

Does this include thermal screens or humidity? No. A screen lowers the effective U value at night; type a lower U to see its effect. The ventilation sum is for sensible heat in dry air.

Is my data uploaded? No. Everything runs in your browser and works offline.

Where the numbers come from

  • Heat balance from first principles: conduction Q = U A ΔT, air exchange Q = ρ cp V̇ ΔT, dry air density from the ideal gas law (R_d = R / M_air), cp of air 1006 J/(kg K), ISA standard atmosphere for pressure at altitude. Unit conversions are exact definitions.
  • Checked against an independent Python version of the sums, with air density and heat capacity from CoolProp (real-gas air): heat loss agrees within 0.01 % and ventilation flow within 0.1 %.
  • Cover U values, fuel energy contents and the example greenhouse are rounded, made-up examples; check your supplier's figures.

Standard scientific values, such as constants, atomic weights and melting points, are facts found in every textbook; we name where ours were checked. If you are an author or publisher and want a value, a credit or a table changed or removed, tell us and we will act quickly.

Last updated 2026-11-09.

Related tools

Evapotranspiration calculator #143 Work out daily reference evapotranspiration (ET0) with the FAO-56 Penman-Monteith equation from temperature, humidity, wind and sunshine or radiation, with shortcuts when humidity or radiation is missing, Hargreaves for comparison, crop water use with your own Kc, and a daily table you paste or open for a month or years of weather. Psychrometric and heat stress calculator #34 From the air temperature and humidity (or dew point, or wet bulb), get every moist air property with the ASHRAE equations, a psychrometric chart, the heat index and the humidex. Irrigation scheduler #383 Paste or open daily reference evapotranspiration (ET0) and rain, describe the soil and crop, and follow the root-zone water balance day by day: when the crop reaches its readily available water, how much to put back, deep drainage after big rain, stress days, and the water to pump. Fume hood and lab ventilation calculator #516 Average a face velocity traverse and flag readings outside the band and ± % you type in, work out the hood's exhaust flow from the sash opening, a room's air changes per hour, how long dilution ventilation takes to bring a vapour down (with a mixing factor K), the steady level from an evaporating liquid, and convert ppm to mg/m³. For study and planning; no limits built in. Crossing plan and pedigree tracker #388 Enter plants and their parents, and planned crosses. The tool checks the pedigree for loops and mistakes, works out every plant's inbreeding coefficient and the coancestry of any two plants (the inbreeding their offspring would have), draws the pedigree, and saves a crossing plan as CSV. Nothing is uploaded. Breeder's equation calculator #389 Predict the response to selection from heritability and the selection differential, or from the proportion selected (selection intensity) and the phenotypic standard deviation, per generation and per year. Estimate heritability from parent-offspring pairs or from families, lines or clones. Nothing is uploaded.