Hair trace metals: statistics when results fall below the detection limit

A 2026 study of barium, strontium and vanadium in children's hair reports medians with a third to three quarters of results below the detection limit. We test those figures with fibub's non-detect statistics tool and show which ones a log-normal can carry.

Every environmental or biomonitoring dataset has results the instrument could not see: “<0.124 µg/g” means the element is somewhere between nothing and the detection limit, and nobody knows where. A 2026 paper in Toxics measured barium, strontium and vanadium in the hair of 120 children and 97 adolescents in an urban-industrial area of Spain, and had to report medians and 95th percentiles when 38 %, 23 % and 74 % of the results were below the limit. The authors did the right thing and used censored-data statistics rather than filling in half the limit. This article puts their published figures through the non-detect statistics tool, shows which of them a log-normal distribution can actually carry, and measures how far the usual shortcut would have taken them. For the limit itself, see the calibration curve; for how many samples you need, the sample size.

The paper in brief

Hair was collected from children aged 6 to 9 and adolescents aged 13 to 16 across four zones, and analysed for barium and strontium (markers of local geology and dust) and vanadium (a marker of heavy oil burning and traffic), with topsoil vanadium measured at the same places.

Detection limits in hair were 0.124 µg/g for barium in children and 0.153 in adolescents, 0.187 and 0.434 for strontium, and 0.02 and 0.011 for vanadium. The share of results below those limits was large: 38.3 % of children’s barium, 23.3 % of strontium and 74.2 % of vanadium. Children’s medians were 0.193 µg/g for barium (95th percentile 0.629), 0.412 for strontium (2.155) and 0.003 for vanadium (0.428).

The statistical rules the authors set out matter as much as the numbers: no substitution; Kaplan–Meier when less than half the results are censored; regression on order statistics (ROS) or maximum likelihood from 50 to 80 %; and above 80 %, report only detection frequency and the upper tail. Barium and strontium differed strongly between zones (p below 1 × 10⁻⁸ with a censored-data test), vanadium did not (p = 0.162). An earlier version of the vanadium data had used half the limit as a filler, and the authors replaced it.

Checked with the tools

Two different checks follow. The first uses only the paper’s published numbers; the second is a simulation, with no data from the paper in it.

Step 1: do the three published facts fit one distribution? For each element the paper gives a median, a 95th percentile and a share below the limit. A log-normal distribution has only two free numbers, so any two of those three fix the third. Matching the median and the 95th percentile for children’s barium gives a spread (σ on the log scale) of 0.718, which puts only 26.9 % below 0.124 µg/g, not 38.3 %. Matching the median and the 38.3 % instead needs σ = 1.487, which would push the 95th percentile up to 2.23 µg/g rather than 0.629. Figure 1 draws both.

Children’s hair barium: two log-normals, three factsChildren’s hair barium: two log-normals, three facts0204060801000.0320.10.3213.2Barium in hair (µg/g, log scale)Results at or below (%)limit of detectionmatches the median and 95th percentilematches the median and the 38.3 % belowfibub.com
Figure 1. The paper's three published facts about barium in children's hair (dots: the median, the 95th percentile and the share below the detection limit) with the two log-normal curves that each match two of them. No single log-normal matches all three.

Children’s barium is the only group where the three facts pull apart like that. Strontium in children comes out at 21.6 % against a reported 23.3 %, adolescents’ barium at 30.0 % against 35.1 %, and vanadium in children at 73.5 % against a reported 74.2 % — almost exact. That pattern makes sense: the vanadium summary came from a fitted, log-normal-based method (ROS or maximum likelihood, by the authors’ own 50 to 80 % rule), so it is internally log-normal by construction, while the barium summary came from Kaplan–Meier, which follows the data’s own shape and owes nothing to a log-normal. The mismatch is not an error in the paper; it is evidence that children’s hair barium really is not log-normal, and so a vote in favour of the distribution-free method they used.

Group Share below the limit, reported What the median and 95th percentile imply
Barium, children 38.3 % 26.9 %
Barium, adolescents 35.1 % 30.0 %
Strontium, children 23.3 % 21.6 %
Vanadium, children 74.2 % 73.5 %

Step 2: what substitution would have cost. We simulated log-normal data with the barium shape (median 0.193 µg/g, σ 0.718, so a true mean of 0.2498 µg/g), 120 results at a time, 300 sets at each censored share, and summarised every set with the tool’s own methods. Figure 2 shows each estimate of the mean divided by the true mean.

Estimates of the mean, as more results go below the limitEstimates of the mean, as more results go below the limit80100120204060Results below the detection limit (%)Estimated mean ÷ true mean (%)the true meanhalf the limitzeroKaplan–MeierROSfibub.com
Figure 2. Simulated data, not the paper's: 300 sets of 120 log-normal results at each censored share, each summarised by the Non-detect statistics tool's own methods. Substitution rules drift as censoring grows; Kaplan-Meier and ROS do not.
  • Substituting zero loses 9.5 % of the mean at 30 % censoring and 41 % at 70 %.
  • Substituting half the limit happens to look good here, within 3 % everywhere, which is why the habit survives. It is luck: the right filler depends on the spread, and this is a mild one.
  • Substituting the full limit gains 6 % at 30 % censoring and 37 % at 70 %.
  • Kaplan–Meier follows exactly the same line as the full limit. That is not a bug: with a single detection limit and no detected value below it, the lowest point in the dataset is the limit, and Kaplan–Meier’s restricted mean has to place the censored mass there. It is the reason Helsel recommends it for data with several limits, and it is why the authors switched to other methods above 50 % censoring.
  • ROS and maximum likelihood stay within about 1 % of the truth all the way to 70 % censoring, because they borrow the shape of the detected values. Of course, that shape has to be right.

Step 3: the median that is not a measurement. Children’s vanadium has 74.2 % of results below 0.02 µg/g and a reported median of 0.003 µg/g, a sixth of the limit. We simulated the same situation (85 of 120 censored) and asked the tool for a median: Kaplan–Meier returns nothing at all, because 71 % of its probability mass sits below the lowest limit and the tool refuses to invent a percentile there. Maximum likelihood returns 0.004 µg/g and ROS 0.0034. Those are extrapolations from the shape of the top quarter of the data, which is exactly what the paper’s own rule says to do between 50 and 80 % censoring, and exactly why it also says to lean on detection frequency at that point. A median of 0.003 µg/g with a limit of 0.02 is a model’s opinion, not an observation, and the paper is right to treat the vanadium zone comparison (p = 0.162) as the weaker of its results.

How we made the graphs

The charts and every number come from scripts/blog-figures/hair-trace-metals-below-detection-limit.mjs in fibub’s public code. It calls kaplanMeier, ros, mleLognormal, substitute and percentile from src/lib/sci/censored.ts, the maths behind the non-detect statistics tool, with normCdf and normInv from src/lib/sci/stats.ts for the log-normal fits.

From the paper: the detection limits, the censored shares, the medians, interquartile ranges and 95th percentiles quoted above. Ours: the 120-result sample size is the paper’s, but the simulated values, the random seed, and the assumption that the underlying distribution is log-normal are all our assumptions, used to measure the methods against a known truth. Figure 2 contains none of the paper’s data.

How we test the maths

On every change to fibub, tests/sci.mjs pins the non-detect methods against Python:

  • On a made-up 16-result set with two limits, the Kaplan–Meier mean must be 2.48125 and its standard error 0.603003, as statsmodels’ SurvfuncRight on the flipped data with a Greenwood variance gives; the median must be 1.5 and the 90th percentile 6.2.
  • ROS must return a mean of 2.428836 and a standard deviation of 2.527843, matching statsmodels’ impute_ros, and the censored log-normal maximum likelihood must give μ = 0.488877 and σ = 0.903271 with a log-likelihood of −18.415341, matching SciPy.
  • When the lowest value in the set is itself a non-detect, the 25th percentile must come back as “not available” rather than as a number.
  • New with this article: our 24-result barium set below must give a Kaplan–Meier mean of 0.3120 µg/g with a standard error of 0.0719, a ROS mean of 0.2897 and a maximum-likelihood mean of 0.2932, and the 85-of-120 vanadium set must return no Kaplan–Meier median at all.

Check it yourself

On the non-detect statistics tool, in the Results card:

  1. Clear the box and paste these 24 made-up results, one per line or separated by spaces (9 of them are non-detects at a limit of 0.124 µg/g, the paper’s barium limit for children): 0.366 0.626 <0.124 <0.124 0.283 0.489 0.3 0.561 <0.124 1.837 0.202 0.164 <0.124 0.177 0.156 <0.124 0.156 0.243 0.327 <0.124 <0.124 <0.124 <0.124 0.484
  2. Set Unit to µg/g. The Summary card reads a Kaplan–Meier mean of 0.312 µg/g, a standard error of 0.0719, a median of 0.164 and an upper 95 % confidence limit of the mean of 0.435 µg/g.
  3. In Every method, compare the rows: ROS mean 0.2897, maximum likelihood 0.2932, half the limit 0.2887, zero 0.2655. The spread between methods, 0.047 µg/g, is about two thirds of one standard error here: with 37.5 % non-detects the method matters less than the sample size does.
  4. The 95th percentile differs much more: 0.626 µg/g from Kaplan–Meier (the largest detected value it can reach) against 1.53 from ROS, which extrapolates a log-normal tail. Upper percentiles are the first thing to go wrong with censored data.
  5. Put 0.5 in Guideline value (optional): the tool counts 3 of 24 results above it. Because the detection limit (0.124) is well below the guideline, every non-detect is safely under it, and the count is exact.
  6. Now change every <0.124 to 0.062 (half the limit). The Kaplan–Meier mean falls from 0.312 to 0.2887, every method in the table reads the same number, and the non-detect count drops to zero: substitution has thrown away the one thing the tool needed to know.

What researchers can use it for

  • Report a censored dataset properly in the browser: Kaplan–Meier, ROS and maximum likelihood side by side, with the substitution results shown only for comparison.
  • Check a published summary for internal consistency, as in step 1: a median, an upper percentile and a censored share must fit together.
  • Decide which method to use from the censored share, following the rule this paper sets out, and see with your own data how much the choice moves the answer.
  • Get an exposure-point concentration: the upper 95 % confidence limit of the Kaplan–Meier mean is what risk assessments usually ask for.
  • Lower the limit instead. If more than half your results are censored, no statistic will rescue them; improve the method with the calibration curve or collect more sample.

The fine print

  • We did not re-analyse the paper’s data. Step 1 uses only its published summary figures, and steps 2 and 3 are simulations.
  • A log-normal is a convention, not a law. Our consistency check shows where the published figures depart from it, which is information about the data, not a mistake in the paper.
  • Kaplan–Meier’s restricted mean cannot fall below the lowest value in the dataset, so with one detection limit it behaves like substituting the full limit. Several limits break that tie.
  • Hair concentrations depend on washing, dyeing and external dust as well as on intake, so nothing here says anything about any child’s exposure or health.
  • The paper’s zone comparisons use censored-data tests we do not reproduce; our checks are about the summary statistics only.

Sources

  • Peña-Fernández, A., Valiente, R., Higueras, M., Moreno-Gómez-Toledano, R. and Lobo-Bedmar, M. C. (2026), Ba-Sr-V as Geogenic and Traffic Tracers in Paediatric Hair from Urban-Industrial Spain, with Co-Located Topsoil Vanadium, Toxics 14(3): 268, doi:10.3390/toxics14030268. Licence CC BY 4.0, checked on the MDPI article page, 2026-11-24. Values used here: 120 children and 97 adolescents; limits of detection in hair 0.124 and 0.153 µg/g (Ba), 0.187 and 0.434 µg/g (Sr), 0.02 and 0.011 µg/g (V); results below the limit 38.3 %, 23.3 % and 74.2 % (children) and 35.1 %, 37.1 % and 51.5 % (adolescents); children's medians (interquartile range) and 95th percentiles Ba 0.193 (0.124-0.350) and 0.629, Sr 0.412 (0.195-0.894) and 2.155, V 0.003 (0.0004-0.0235) and 0.428 µg/g; adolescents' Ba 0.287 (0.153-0.948) and 2.061 µg/g; methods: no substitution, Kaplan-Meier below 50 % censoring, ROS or maximum likelihood from 50 to 80 %, detection frequency above 80 %, analysed in R with NADA2.
  • Methods for censored environmental data: Helsel, D. R., Statistics for Censored Environmental Data (Wiley, 2nd ed. 2012): Kaplan-Meier on flipped data, robust regression on order statistics, and maximum likelihood.

If you are an author or publisher and want a credit or a passage changed or removed, tell us and we will act quickly.