89 nominal metabolite hits, none after FDR: what noise gives
A seminal plasma metabolomics study tested 2,612 metabolites in 10 against 9 men and found none after correction. We show that pure noise gives about 89 nominal hits.
Untargeted metabolomics measures thousands of small molecules at once, which makes it easy to find something in a small study, and just as easy to find nothing real. A 2026 study in Frontiers in Endocrinology compared seminal plasma from 10 men with impaired semen quality and 9 controls across 2,612 annotated metabolites, found 89 that passed a nominal screen, and then reported that none survived a false-discovery-rate correction. The authors present it honestly as exploratory. This article puts numbers on why: with 10 against 9 samples, how many “hits” does a table with nothing in it give, and what does a real difference have to look like before the correction lets it through? The maths is in the volcano and PCA tool; for planning groups see randomisation list generator, and for the quantitative side of a measured peak, calibration curve.
The paper in brief
In the discovery cohort the researchers ran untargeted LC-MS/MS on 10 men with impaired semen quality and 9 men with normal semen quality. They kept 2,612 putatively annotated metabolites and screened for a fold change of at least 1.5 in either direction and a nominal p below 0.05. That gave 89 metabolites, 22 higher and 67 lower in the impaired group. After Benjamini-Hochberg correction, no single metabolite had q below 0.05. Pathway analyses pointed to nucleotide and nucleoside processes as ideas to follow up.
An independent HPLC-UV cohort of 18 against 18 men measured two candidates. 2-HMBA was lower in the impaired group (median 211 against 358 micrograms per millilitre), with p = 0.030 but q = 0.060 after correction, and an area under the curve (AUC) of 0.713. Cytidine showed no difference (p = 0.812, q = 0.812). The authors say plainly that these are hypothesis-generating signals, not biomarkers.
Checked with the tools
All tables below are made-up (simulated by our script) and run through the same Welch t-tests and Benjamini-Hochberg correction as the volcano and PCA tool. Nothing here is the study’s data, which we do not have.
Step 1: the paper’s two q-values, by hand. With two tests, Benjamini-Hochberg multiplies the smaller p by 2 and the larger by 1 (then keeps the order). So p = 0.030 becomes q = 0.060 and p = 0.812 stays 0.812. The tool’s correction gives exactly these, which matches the paper’s two published q-values and tells us the HPLC-UV step corrected over just two metabolites, not over the whole table.
Step 2: how many hits does noise give? We built tables of 2,612 metabolites, 10 against 9 samples, where the groups do not differ at all, and let the noise (the standard deviation of log2 intensity) vary. Averaging 8 tables per point, the number passing the paper’s screen rises with the noise and reaches 89 at a log2 standard deviation of about 0.67, which means individual readings typically differ from the metabolite’s level by a factor of about 1.6. The ceiling is the 5 % of all tests that fall below p = 0.05 by chance: about 125 raw hits in our tables, against 131 expected.
So the paper’s 89 nominal hits are exactly what a null table gives at ordinary biological noise. In our noise-only tables the smallest corrected q averages 0.65, and none of the 8 tables had any metabolite below 0.05. That agrees with the paper’s finding of no survivors, and it is a measure of how little the nominal screen alone tells us.
Step 3: what could have survived? With 2,612 tests, one test must reach p below about 1.9 x 10^-5 (0.05 divided by 2,612) to be sure of q below 0.05 on its own. To see what that asks of the data, we hid 100 real differences among the 2,612 tests at the same noise, and counted how many pass.
| True fold change (log2 / factor) | Real differences found at raw p < 0.05 | Found at q < 0.05 |
|---|---|---|
| 0.5 (1.4x) | 34 % | 0 % |
| 1.0 (2x) | 86 % | 14 % |
| 1.5 (2.8x) | 99.6 % | 82 % |
| 2.0 (4x) | 100 % | 99 % |
With 10 against 9 and this noise, a metabolite must be about 2.8 times higher or lower to be found reliably after correction, and a doubling is found only one time in seven. Smaller shifts, which are the usual size in a human biofluid, cannot pass, however real they are. The “no survivors” result is therefore not evidence of no differences; it is evidence the study was small.
Step 4: the HPLC-UV step, and what AUC says. The 2-HMBA result of AUC 0.713 in 18 against 18 corresponds to a Mann-Whitney p of about 0.029 by the normal approximation (our arithmetic), matching the paper’s 0.030. The discovery-cohort AUCs of 0.900 and 0.889 in 10 against 9 correspond to p of about 0.003 and 0.004: striking for one metabolite, but far above the 1.9 x 10^-5 needed across 2,612 tests, which is how a high AUC and a q above 0.05 can sit together.
| Check | Paper says | Tool or our arithmetic gives |
|---|---|---|
| BH of p = 0.030 and 0.812 | q = 0.060 and 0.812 | 0.060 and 0.812 |
| Nominal hits in 2,612 tests | 89 | 89 from pure noise at log2 SD 0.67 |
| Raw p < 0.05 by chance | not stated | about 125 (131 expected) |
| Smallest p for q < 0.05 | not stated | 1.9 x 10^-5 |
| p from AUC 0.713, 18 against 18 | 0.030 | about 0.029 |
How we made the graphs
The charts and numbers come from scripts/blog-figures/seminal-plasma-metabolomics-2612-tests-bh-fdr-10-vs-9.mjs in fibub’s public code. It calls compare (which runs welch on log2 values and then bh) from src/lib/sci/mbvolcano.ts, the maths behind the volcano and PCA tool, and normCdf from src/lib/sci/distributions.ts for the AUC arithmetic. From the paper: the group sizes 10 and 9, the 2,612 tests, the fold change cut 1.5, the 89 hits, the two HPLC-UV p and q values and the AUCs. Ours: the table model (a log2 mean for each metabolite around 10 with a spread of 3, plus independent noise), the noise levels, the 100 hidden real differences, and every random seed. The tables are simulated.
How we test the maths
On every change to fibub, tests/sci.mjs runs tests/sci-tools/metabolite-volcano-pca.mjs, which pins the table reader, the missing-value rules, the Benjamini-Hochberg step-up, Welch’s test and the PCA against NumPy and pandas. New with this article, it also checks that p = 0.030 and 0.812 give q = 0.060 and 0.812, and that our seed-1 null table of 2,612 metabolites (10 against 9) keeps giving 160 raw p below 0.05, 115 passing the paper’s screen and a smallest q of 0.585.
Check it yourself
On the volcano and PCA page, with the built-in example (12 metabolites, 4 against 4):
- Leave the example table in the box and set Significant when to raw p, is below 0.05 and and fold change at least (x) 1: six metabolites pass.
- Switch Significant when to FDR q (Benjamini-Hochberg): still six, because with only 12 tests the correction is mild. Citrate shows p of about 0.0167 and q of about 0.033, which is p times 12 over its rank of 6.
- Set and fold change at least (x) to 2: five remain, since Citrate’s fold change is 0.80.
- Now think of 2,612 rows instead of 12: the same correction would multiply the p-values by up to 2,612 over their rank, which is why 10 against 9 samples cannot pass.
What researchers can use it for
- Judge a small omics study before you run it. Decide the smallest fold change you care about, then use a simulation like ours to see if your group size can find it after correction.
- Report both numbers. Give the nominal count and the corrected count, as this paper does, so readers see how much of the list is chance.
- Audit a published table. The tool recomputes q from p (it must be p times the number of tests over the rank, then made monotone) so a reported q that does not follow from the stated number of tests is easy to spot.
- Choose between a screen and a test. If a list of nominal hits is only for generating ideas, say so, as the authors did; confirm with an independent method in a second cohort.
- Teach multiple testing with a table of random numbers that still gives “significant” lists.
The fine print
- Our tables are simulated with a lognormal model and independent metabolites. Real metabolites are correlated, which changes the spread of the number of chance hits but not the average.
- The noise level of 0.67 (log2) is our assumption, tuned so that noise alone gives the paper’s 89 nominal hits. It shows that 89 is plausible under no differences, not that there were none.
- The paper’s analyses (including its pathway work and the choice of which p-values were corrected) may differ in detail from the plain Welch and Benjamini-Hochberg steps we used.
- The AUC-to-p step uses the normal approximation to the Mann-Whitney test with no ties; the paper’s own p-values come from its own software.
- This article is about statistics. It is not medical advice or a statement about male fertility.
Sources
- Xu J, Guo L, Xiong L, Li J, Wu P, Ma Y, Yang J, Du Y (2026), Exploratory seminal plasma metabolomics and independent HPLC-UV evaluation in men with impaired semen quality, Frontiers in Endocrinology 17, doi:10.3389/fendo.2026.1909718. Licence CC BY 4.0 (Crossref record, checked 2026-11-24; the publisher page text did not show a licence line); no update-to entry in Crossref. Values used here: discovery cohort of 10 men with impaired semen quality and 9 normozoospermic controls (untargeted LC-MS/MS); 2,612 putatively annotated metabolites tested; nominal screen of p < 0.05 with fold change at least 1.5 or at most 0.67 gave 89 metabolites (22 higher, 67 lower in the impaired group); no metabolite reached Benjamini-Hochberg q < 0.05; HPLC-UV cohort of 18 against 18, with 2-HMBA median 358 (controls) against 211 (impaired) ug/mL, p = 0.030, q = 0.060, post hoc AUC 0.713 (95 % CI 0.540 to 0.886) and cytidine p = 0.812, q = 0.812; discovery-cohort post hoc AUCs 0.900 (2-HMBA) and 0.889 (cytidine). The authors call the findings exploratory and not validated biomarkers. Group sizes and statistics only; no data table is reproduced here.
If you are an author or publisher and want a credit or a passage changed or removed, tell us and we will act quickly.