Can a 3.7 % fall in EMG median frequency be seen in one window?

An esports study reports wrist-extensor median frequency falling from 99.2 to 95.6 Hz over a long session. We simulate 10 second windows to see how noisy that number is.

Esports players sit for hours, and their wrists do small repeated movements all the while. A 2025 study followed 32 competitive players through two long gaming sessions and used surface electromyography (EMG, the electrical signal of a muscle) to see whether their wrist extensors tired. The sign used is the median frequency of the EMG spectrum, which drifts downwards as a muscle fatigues. The reported drop is small: about 3.7 %, or 3.65 Hz. This article asks a practical question the paper’s group averages can’t answer on their own: how noisy is one median-frequency reading, and what does it take to see a change that small? For the signal-processing side see EMG analyser, notch filter and FFT workbench.

The paper in brief

Thirty-two healthy men played two competitive sessions of 90 to 120 minutes each, with a 10 minute break between them. Electrodes on the wrist extensors and the upper trapezius recorded EMG at 2000 Hz, filtered from 4 to 450 Hz with a 50 Hz notch. The team computed the median frequency (MDF), the frequency that splits the spectrum’s power in half, from a fast Fourier transform over 10 second periods, and the amplitude (RMS, as a percentage of a maximal voluntary contraction) over the first and last 5 minutes of each game.

The left wrist extensor’s MDF fell from 99.24 to 95.59 Hz (-3.7 %) and the right’s from 97.86 to 94.60 Hz (-3.3 %), both with p below 0.001 and eta-squared (the share of variance explained) of 0.23 and 0.28. The normalised RMS fell too, by about 16 %. The upper trapezius showed no clear change once the post-hoc tests were done. The authors read the falling MDF as progressive wrist extensor fatigue that was not recovered during the break.

Checked with the tools

The paper gives group means, not signals, so we cannot re-run its analysis. What we can do is ask how well the EMG analyser‘s own window maths could see a shift of this size in a recording like theirs. All the signals below are made-up EMG from the tool’s built-in generator, set to the paper’s 2000 Hz rate and 10 second windows; the spectrum shape is our assumption, a smooth one-pole shape.

Step 1: tune the made-up muscle to the paper’s numbers. The generator has a spectral corner frequency that sets how much power sits at high frequencies. Averaging 40 independent 10 second windows per setting, the tool’s median frequency rises almost in step with that corner. Bisecting to the paper’s left extensor values gives a corner of 87.6 Hz for the start (MDF 99.2 Hz) and 81.7 Hz for the end (95.6 Hz).

Median frequency of made-up wrist EMGMedian frequency of made-up wrist EMG60801001206080100120Spectral corner of the model muscle (Hz)Window median frequency (Hz)paper start 99.24 Hzend 95.59 Hzfibub.com
Figure 1. The tool's window median frequency against the corner of our model spectrum, averaged over 40 made-up recordings per point. The dashed lines are the paper's group means for the left wrist extensor.

Step 2: how noisy is one window? We then drew 100 new independent windows at each state, measured with a 512-sample Welch segment (0.256 s) over the band 20 to 450 Hz. The windows’ median frequencies scatter with a standard deviation of 2.5 Hz at the start and 2.3 Hz at the end, against a true shift of 3.65 Hz. The mean difference of our 100 windows is 3.9 Hz, so the average is right, but a single late window reads higher than a single early one 13 % of the time.

One 10 second window each, 40 repeatsOne 10 second window each, 40 repeats9095100105110203040Repeat numberWindow median frequency (Hz)start (99.2 Hz)end (95.6 Hz)fibub.com
Figure 2. One 10 second window per dot. The start and end states differ by 3.65 Hz on average, but single windows scatter by almost as much, so a decline shows only after averaging.

Step 3: how much averaging is needed. To bring the standard error of the difference down to a quarter of the shift, each state needs about 14 windows of 10 seconds, or 2.3 minutes of signal. The paper analysed the first and last 5 minutes of each game, which is 30 windows per period, comfortably more than that, so a significant group result is no surprise. A single 10 second reading from one player would not have been.

Step 4: the segment length matters as much as the effect. The same made-up signal, measured with different Welch segment lengths, gives mean median frequencies of 96.95 Hz (256 samples), 99.24 Hz (512), 99.81 Hz (1024) and 100.18 Hz (2048). The choice of segment moves the reading by up to 3.2 Hz, nearly the size of the whole reported fatigue effect. Comparisons are safe only when the same settings are used throughout; the absolute value of an MDF is not comparable between papers unless the method matches.

Check Paper says Tool gives
Left extensor MDF, start to end 99.24 to 95.59 Hz (-3.7 %) tuned to 99.2 and 95.6 Hz (corner 87.6 and 81.7 Hz)
Scatter of one 10 s window not stated standard deviation about 2.4 Hz
Windows needed per state (SE of difference at a quarter of the shift) not stated about 14
Effect of Welch segment length on MDF not stated 96.95 to 100.18 Hz for 256 to 2048 samples

The amplitude result goes the other way from the usual textbook picture, in which EMG amplitude rises with fatigue as more muscle fibres are recruited. In this seated, low-force task the normalised RMS fell by about 16 %. The tool’s windows also give RMS, but we did not simulate amplitude: we have no model of how a keyboard-and-mouse task changes it.

How we made the graphs

The charts and numbers come from scripts/blog-figures/wrist-extensor-median-frequency-esports-emg-welch-window-detectability.mjs in fibub’s public code. It calls synthEmg (the tool’s made-up EMG generator) and fatigue, which in turn use welch and meanMedian, all from src/lib/sci/emg.ts, the maths behind the EMG analyser. From the paper: the 2000 Hz sampling rate, the 10 second window, the 50 Hz notch and the left extensor’s MDF at the start and end. Ours: the one-pole spectral shape, the 20 to 450 Hz band (the generator has a 20 Hz high-pass, so we did not use the paper’s 4 Hz edge), the Welch segment of 512 samples and every seed. The signals are simulated, never the study’s recordings.

How we test the maths

On every change to fibub, tests/sci.mjs runs tests/sci-tools/emg-analyser.mjs. It pins the FFT to a direct DFT, the Welch density to a pure 100 Hz sine (total power A squared over two) and the mean and median frequency to SciPy’s spectra, the moving RMS to NumPy, and the fatigue slope to scipy.stats.linregress (-1.419 Hz/s on the built-in example). New with this article, it also pins our 10 second windows: the average median frequency over seeds 1 to 10 must stay at 94.85 Hz for a corner of 80 Hz and 101.06 Hz for 90 Hz, and the Welch segment must keep moving the same signal from 92.85 Hz (256 samples) to 96.21 Hz (2048 samples).

Check it yourself

On the EMG analyser page:

  1. Press Use the example to load the 32 second made-up recording.
  2. Set Welch segment to 256 and read the median frequency slope in the fatigue panel: about -1.42 Hz/s.
  3. Change Welch segment to 128 and then 512: the slope becomes about -1.51 and -1.35 Hz/s, and the first window’s median frequency moves between roughly 140 and 143 Hz. The same signal gives different numbers for different segment lengths.
  4. Set Window length (s) to 10 (and Move the window by (s) to 5) with Sample rate (Hz) at 1000 for the example, to see how few windows a 32 second recording leaves.
  5. Press Download windows (CSV) to take every window’s mean and median frequency into your own spreadsheet and compute the scatter yourself.

What researchers can use it for

  • Plan a fatigue study. Estimate the scatter of one window from a pilot recording, then work out how many windows per time point you need for the shift you expect.
  • Report the method with the number. Give the window length, segment length, band and notch next to every median frequency, since the same signal reads up to 3 Hz differently.
  • Check a filter chain before comparing sessions: notch filter shows what a mains notch does to the spectrum, and FFT workbench lets you look at the full spectrum of a recording.
  • Teach why group means can be significant when single readings are not, with the 13 % flip rate as a concrete example.
  • Follow a fatigue slope within one contraction by sliding the tool’s window across a burst and reading the trend line.

The fine print

  • Our recordings are simulations with a smooth one-pole spectrum; real wrist EMG has crosstalk, movement artefacts and subject variation that would add to the scatter.
  • We used a 20 to 450 Hz band, not the paper’s 4 to 450 Hz, and one Welch segment length; the paper’s FFT settings may give a different level of noise.
  • The paper’s effect sizes are for 32 players averaged; the scatter between players is not in our model and is not given in the paper’s text.
  • This article is about the maths of a published measurement. It is general education about signal processing, not advice about posture, training or health.

Sources

  • Tholl C, Hansen L, Froboese I (2025), Wrist extensor fatigue and game-genre-specific kinematic changes in esports athletes: a quasi-experimental study, BMC Sports Science, Medicine and Rehabilitation, doi:10.1186/s13102-025-01305-0. Licence CC BY 4.0 (Crossref record, checked 2026-11-24; the publisher page shows open access and the Author(s) copyright line without naming the licence); no update-to entry in Crossref. Values used here: 32 healthy male esports athletes; two competitive sessions of 90 to 120 minutes with a 10 minute passive break; surface EMG sampled at 2000 Hz, 4th-order Butterworth band-pass 4 to 450 Hz with a 50 Hz notch; median frequency (MDF) from a fast Fourier transform over 10 second periods; first and last 5 minutes of each game analysed; left wrist extensor MDF 99.24 to 95.59 Hz (-3.7 %, p < 0.001, eta squared 0.23) and right 97.86 to 94.60 Hz (-3.3 %, p < 0.001, eta squared 0.28) between the first and last time points; normalised RMS 4.62 to 3.89 % MVC (left) and 5.64 to 4.70 % MVC (right). Group means only; the athletes' own recordings are not used.

If you are an author or publisher and want a credit or a passage changed or removed, tell us and we will act quickly.

Tools in this article

Read next