Bacillus subtilis spores in soy milk: D-values, z-values and pressure
A 2025 study shows mild high pressure makes Bacillus spores in soy milk easier to kill with heat. We refit its z-values and check its matched heat treatments with fibub's F0 tools.
Bacterial spores are the hardest thing a food maker has to kill. A Bacillus subtilis spore can sit through boiling water for minutes and then grow once the food cools. A 2025 paper in Microorganisms tests a gentler route for soy milk: squeeze the spores at a modest pressure first, which wakes many of them up (germination) and makes them easy to kill, then heat what is left. The paper’s numbers are classic heat-kill numbers, D-values and z-values, which is exactly what the autoclave F0 and the f-value calculator work with. This article refits the z-values from the paper’s D-values and checks how its heat steps compare. To count the survivors on plates yourself, use the CFU counter.
The paper in brief
Spores of B. subtilis were mixed into soy milk at about 7.4 log CFU/mL (25 million living spores per millilitre; CFU means colony-forming units). Two kinds of samples were then heated at 80, 87 and 100 °C: untreated spores, and spores that had first been held at 100 MPa (about 1,000 times air pressure, far below the 400 to 600 MPa used for cold-pressed juices) at 65 °C for 30 minutes.
Two terms carry the paper:
- The D-value is the time at one temperature that kills 90 % of the spores (one “log”).
- The z-value is how many degrees hotter makes that kill ten times faster.
Pressure alone cut the count by about 3.6 to 3.9 logs. The spores that survived it were also easier to kill with heat: their D-value at 87 °C halved, from 20 to 10 minutes, and the z-value rose a little, from 7.5 to 8.2 °C. The order matters: heating before the pressure step made pressure work worse, because a heat shock left the spores harder to germinate. Hotter, shorter pre-heats did the most harm: after 4 minutes at 100 °C, pressure removed almost nothing. The author’s suggestion is pressure first, mild heat after.
Checked with the tools
All of this is a recomputation from values stated in the paper. We used no measured survivor curves.
Step 1: the z-values. The F-value calculator fits a straight line to the logarithm of D against temperature. From the three untreated D-values it gives z = 7.54 °C (R² 0.991); from the pressure-treated ones, 8.27 °C (R² 0.980). The paper reports 7.5 and 8.2 °C. Figure 1 shows the points and lines. The pressure-treated line sits lower at every temperature, but the two lines come together near 100 °C (fitted D 0.53 against 0.43 minutes). That is the paper’s point in one picture: pressure helps most at milder heat.
Step 2: is the line really straight? Three points can still bend. Move the measured 100 °C D-value (0.6 min) down to 87 °C with z = 7.5 °C and the tool gives 32.5 minutes, against 20 minutes measured. At 80 °C it gives 278 minutes, against 300 measured. So the 87 °C point sits below the line, and the fitted line (D 28.2 min at 87 °C) is a compromise. With only three temperatures this is normal scatter, but it shows why a z-value from three points should be quoted loosely.
Step 3: the “matched” pre-heats. To compare pre-heats fairly, the paper used three that should kill about the same: 420 min at 80 °C, 30 min at 90 °C and 1.5 min at 100 °C. The F0 tool’s equivalent-time maths says 1.5 minutes at 100 °C matches 32.3 minutes at 90 °C and 696 minutes at 80 °C with z = 7.5 °C, or 24.9 and 412 minutes with z = 8.2 °C (Figure 2). So the 90 °C step fits the untreated z, while the 80 °C step is closer to the pressure-treated z. The measured counts agree that the three steps were similar: they fell by 1.8, 1.6 and 1.7 logs.
Step 4: predicted against measured kill. Run each pre-heat as a steady hold through the tool’s organism-kill maths (D 0.6 min at 100 °C, z 7.5 °C) and it predicts 1.51, 2.32 and 2.50 logs for the 80, 90 and 100 °C steps. With the fitted line instead, the predictions are 1.75, 2.66 and 2.82. The measured 1.6 to 1.8 logs sit at the low end, below the 90 and 100 °C predictions. One likely reason, and our assumption: a short pre-heat in a tube spends part of its time warming up, so 1.5 minutes “at 100 °C” delivers less than 1.5 minutes of full lethality. A logged temperature trace in the F0 tool would settle that.
Step 5: what pressure buys at 87 °C. To bring the count down to the detection limit (1.0 log CFU/mL, so 10 per mL), untreated spores need 6.4 logs of kill and pressure-treated ones only 2.6. At their own 87 °C D-values that is about 128 minutes against 26 minutes: five times shorter for the same end point.
| Check | Paper | Our tool result |
|---|---|---|
| z-value, untreated | 7.5 °C | 7.54 °C (R² 0.991) |
| z-value, after pressure | 8.2 °C | 8.27 °C (R² 0.980) |
| 1.5 min at 100 °C, as time at 90 °C | 30 min used | 32.3 min (z 7.5), 24.9 min (z 8.2) |
| 1.5 min at 100 °C, as time at 80 °C | 420 min used | 696 min (z 7.5), 412 min (z 8.2) |
| Kill in the matched pre-heats | 1.6 to 1.8 logs measured | 1.51 to 2.50 logs predicted (D 0.6, z 7.5) |
| Minutes at 87 °C to the detection limit | not stated | 128 untreated, 26 after pressure |
How we made the graphs
The charts and every number come from scripts/blog-figures/bacillus-subtilis-spores-soy-milk-d-value-z-value-pressure.mjs in fibub’s public code. It calls zValue from src/lib/sci/thermproc.ts (the maths of the f-value calculator) for the z-value lines, and dAt, equivalentTime, organismKill, neededLR and timeFor from src/lib/sci/f0.ts (the maths of the autoclave F0) for everything else.
The D-values, z-values, pre-heat times, counts and detection limit come from the paper’s text and tables. Treating each pre-heat as a perfectly steady hold is our assumption; the paper does not give temperature traces.
How we test the maths
On every change to fibub, tests/sci.mjs runs tests/sci-tools/f0-calculator.mjs and tests/sci-tools/thermal-process-calculator.mjs. Among their checks:
- F0 totals for a made-up autoclave log must match an independent NumPy script: 27.65 minutes at the chamber probe and 22.10 at the load centre.
- A D-value of 1.5 min at 121.1 °C with z = 10 °C must move to 0.15 min at 131.1 °C and 15 min at 111.1 °C.
- The z-value fit on four made-up D-values must match NumPy’s
polyfit: z 9.925 °C. - New with this article: 1.5 minutes at 100 °C with z = 7.5 °C must equal 32.32 minutes at 90 °C and 696.2 at 80 °C, a D-value of 0.6 min at 100 °C must move to 32.47 min at 87 °C, and a 1.5-minute hold must give 2.5 logs.
Check it yourself
On the autoclave F0:
- Clear the Temperature log box and paste three lines: Minutes,Bath, then 0,100, then 1.5,100.
- Under Settings, set Reference temperature (°C) to 100, z-value (°C) to 7.5, Hold from (°C) to 100 and Equivalent time at (°C) to 90. The F0 card shows 1.5 minutes and an equivalent of about 32.32 minutes at 90 °C.
- In Kill of one organism, type D-value (min) 0.6, D measured at (°C) 100, Organism z (°C) 7.5, Organisms per item at the start 2.5e7 and Target SAL 10 (the detection limit, 10 per mL). It reads 2.5 log reduction, about 79,100 left, and 6.398 logs needed.
- Set Plan at (°C) to 87: the D-value there is about 32.47 minutes and the hold for the target about 207.7 minutes. Change D-value (min) to 20 and D measured at (°C) to 87 (the measured value) and see how much the plan changes.
On the f-value calculator, in z-value from D-values, type 80, 300, 87, 20 and 100, 0.6 (one per line): it gives a z-value of about 7.54 °C.
What researchers can use it for
- Get a z-value with its fit quality from your own D-values, and see which point pulls the line, with the f-value calculator.
- Design matched heat treatments: pick holds at different temperatures with the same lethality before an experiment, with the equivalent-time box of the autoclave F0.
- Turn a real temperature trace into a kill: paste a logged water-bath or retort trace (several probes at once) and get each probe’s log reduction for your organism.
- Plan a hold time for a target number of survivors at any temperature, then check it on plates with the CFU counter.
- Teach thermal death time: D, z and F side by side on one page, with numbers students can change.
The fine print
- This is a recomputation from the paper’s stated D-values and counts. We did not have the survivor curves.
- The z-value fits use three temperatures each, so a small change in one D-value moves z noticeably.
- Treating each pre-heat as a steady hold is our assumption; real tubes take time to warm up.
- The F0 tool’s straight-line (log-linear) model ignores the shoulders and tails that spore survivor curves often show.
- This is general food science education, not a validated process. Real food processes are set by a qualified process authority.
Sources
- Morimatsu, K. (2025), Combination of Medium-High-Hydrostatic-Pressure Treatment with Post-/Pre-Heat Treatment for Pasteurization of Bacillus subtilis Spore Suspended in Soy Milk, Microorganisms 13(7): 1469, doi:10.3390/microorganisms13071469. Licence CC BY (Creative Commons Attribution), checked on the MDPI article page, 2026-11-24. Values used here: D-values of 300, 20 and 0.6 min (untreated) and 150, 10 and 0.5 min (after pressure) at 80, 87 and 100 °C; stated z-values 7.5 and 8.2 °C; pressure step 100 MPa at 65 °C for 30 min; pre-heats of 80 °C for 420 min, 90 °C for 30 min and 100 °C for 1.5 min, leaving 5.6, 5.8 and 5.7 log CFU/mL; starting count 7.4 log CFU/mL; 3.6 log CFU/mL after pressure; detection limit 1.0 log CFU/mL.
- D-value, z-value and equivalent lethality: Stumbo, C. R. (1973), Thermobacteriology in Food Processing, 2nd ed., Academic Press.
If you are an author or publisher and want a credit or a passage changed or removed, tell us and we will act quickly.