Transducers and detectors

Experimental methods · 3 questions and templates for IIT JAM Physics, in order from warm-up to top rank. Check each answer, then read the full solution.

Loading questions… (they need JavaScript; nothing you type is sent anywhere)

Written questions with solutions

The same questions as a list, so you can print them or read without the practice box. Templates (fresh numbers) appear only in the practice box above.

  1. MCQWarm-up

    Which of these transducers is self-generating (active), producing its electrical signal without any external excitation?
    1. a metal-foil strain gauge
    2. a thermistor
    3. a piezoelectric crystal
    4. a linear variable differential transformer (LVDT)
    Answer and solution

    Answer: C

    A piezoelectric crystal produces charge directly when stressed. A strain gauge and a thermistor only change resistance, which must be read with a current or bridge supply, and an LVDT needs an AC excitation on its primary. Thermocouples and photovoltaic cells are other self-generating sensors.

    Why people get this wrong: An LVDT has an output coil, but it delivers nothing until its primary is driven.

  2. MCQStandard

    A small amount of a halogen or organic vapour is added to the gas of a Geiger-Müller tube. Its purpose is
    1. to raise the gas gain
    2. to absorb gamma rays
    3. to make the tube sensitive to slow neutrons
    4. to stop each discharge so the tube can reset after a pulse
    Answer and solution

    Answer: D

    After an avalanche, positive ions drifting to the cathode, and UV photons from the discharge, could free new electrons and restart the discharge endlessly. The quench molecules absorb the UV photons and take over the ions' charge, then dissociate harmlessly, so each event gives one pulse. Halogen quenchers recombine, so halogen tubes last much longer than organic-quenched ones.

    Why people get this wrong: The gain in a GM tube is already saturated; the quench gas controls the end of the discharge, not its size.

  3. MSQExam level

    Which statements about temperature sensors are correct?
    1. Some thermocouples can measure well above 1000∘C, beyond the range of platinum resistance thermometers in normal use.
    2. Near room temperature an NTC thermistor's resistance changes by a few percent per kelvin.
    3. A platinum resistance thermometer's resistance rises by about 0.4% per kelvin.
    4. A thermocouple's output depends only on the temperature of its hot junction.
    Answer and solution

    Answer: A, B, C

    Type B, R and S thermocouples work up to about 1600 to 1800∘C. A thermistor with B≈3500 K has α=−B/T2≈−3.9% per kelvin at 300 K. Platinum has α=0.00385 K−1. A thermocouple measures the difference between its two junctions, so the reference junction temperature must be known or compensated.

    Why people get this wrong: Forgetting the reference junction: a thermocouple is a differential thermometer.