Off-grid solar for a Tier 3 home in Ethiopia: the PV and battery sizing checked
A 2026 study sizes a 12 V solar home system for 1.7 kWh a day in rural Ethiopia. We redo its array, battery bank and controller sums and find where 400 Wp and 4 × 130 Wp part ways.
Hundreds of millions of rural homes are far from any power line, and a small solar home system (a few panels, a battery, a charge controller and an inverter) is often the quickest way to light, a fridge and phone charging. The World Bank’s multi-tier framework grades such access from Tier 1 (a lamp and a phone) to Tier 5; Tier 3 adds a fridge and small kitchen appliances. A 2026 paper in Energies designs Tier 2 and Tier 3 systems for villages in Ethiopia and gives every step of its sizing in words, so the battery solar sizing tool can redo each one. For the step before, estimate what a panel really yields with the solar PV yield tool; for a grid-tied home, simulate a battery hour by hour with home battery.
The paper in brief
The authors compared four solar data sources for the region (annual means from 4.22 to 6.54 kWh/m²/day, and 7.30 from a 13-year PVGIS average), built hourly load profiles for Tier 2 and Tier 3 homes, and sized a 12 V system for the worst case: 4.8 peak sun hours (the hours of full 1000 W/m² sun that give a day’s energy). Their Tier 3 home uses about 1.7 kWh a day: roughly 40 to 50 W overnight when only the fridge runs, 80 W in the early morning, 50 to 60 W through the day and 110 to 120 W in the evening.
The sizing method, in their words: multiply the demand by 1.15 to 1.2 for losses, divide by the overall system efficiency (85 %) and by the worst-case sun hours to get the array; multiply by 3 days of autonomy (days with no sun) and divide by an 85 % maximum depth of discharge (how much of the battery may be used) to get the bank. The headline result is a 400 Wp array with a 2 × 250 Ah battery bank, built as four 130 Wp modules with a 35 to 40 A charge controller, giving more than 60 % surplus energy over the year. They also find lithium iron phosphate batteries cheaper over the system’s life for loads above 1.5 kWh a day.
Checked with the tools
We put the paper’s own numbers through the maths of the Battery solar sizing tool. This is a recomputation from values in the text; we did not have the paper’s spreadsheets or its appliance table.
Step 1: the load. Adding up the paper’s four load bands over 24 hours (8 h overnight, 2 h morning, 8 h day, 6 h evening) gives 1540 Wh at the low ends, 1650 Wh in the middle and 1760 Wh at the high ends. The paper’s 1.7 kWh design value sits inside that, and its Tier 3 range of 1.43 to 1.68 kWh is consistent. (The hours of each band are our reading of the text.)
Step 2: the array. Following the method all the way (1700 Wh × 1.15, ÷ 0.85, ÷ 4.8 h) needs 479 W; with the 1.2 factor, 500 W. Rounded up to 130 Wp modules, both give four modules, 520 Wp, exactly the paper’s final setup. The stated 400 Wp only comes out if one of the two factors is left out: 1700 × 1.15 ÷ 4.8 = 407 W, or 1700 ÷ 0.85 ÷ 4.8 = 417 W. So the paper’s two array figures follow two different versions of its own method, and they are not the same size: 400 Wp gives 1632 Wh a day at 4.8 h and 85 %, less than the 1700 Wh load, while 520 Wp gives 2122 Wh, enough even with the 1.15 factor (1954 Wh).
Step 3: the battery bank. 1700 Wh × 3 days ÷ 0.85 is 6000 Wh, or 500 Ah at 12 V, which is exactly 2 × 250 Ah. With the 1.15 factor carried through, the bank grows to 575 Ah (6897 Wh) and needs a third battery. Figure 1 shows how strongly the bank depends on the usable depth of discharge: at 50 %, a common limit for long life with lead-acid batteries, the same three days need 850 Ah. The 85 % in the design suits lithium iron phosphate, which is the chemistry the paper recommends at this load.
Step 4: the charge controller. The tool’s rule, array watts ÷ system volts × 1.25, gives 54.2 A for 520 Wp at 12 V (43.3 A with no margin) and 41.7 A for 400 Wp. The paper instead divides the day’s energy by 5.5 h and by 12 V, which gives 34.8 to 36.4 A, matching its 35 to 40 A. That rule sizes the controller for the average current, not for the array’s peak, so a 35 to 40 A unit would clip a 520 Wp array on clear middays. It is worth checking the module’s short-circuit current before buying.
Step 5: the surplus. Figure 2 plots the daily energy of both arrays against sun hours. For four 130 Wp modules to make 60 % more than the 1.7 kWh load, the year must average 6.15 peak sun hours (7.07 if the 1.15 factor is counted), inside the high end of the paper’s solar estimates (6.54 and 7.30). A 400 Wp array would need 8.0 hours, more than any of them. So the paper’s “over 60 % surplus” fits the 520 Wp system it built, not the 400 Wp figure in its abstract.
| Check | Paper | Tool gives |
|---|---|---|
| Daily load from the load bands | 1.7 kWh (design) | 1540 to 1760 Wh |
| Array, full method (×1.15, ÷0.85, ÷4.8 h) | 4 × 130 Wp | 479 W needed: 4 × 130 Wp = 520 Wp |
| Array, headline figure | 400 Wp | 407 W (×1.15 only) or 417 W (÷0.85 only) |
| Battery bank, 3 days at 85 % | 2 × 250 Ah | 500 Ah (575 Ah with ×1.15) |
| Charge controller | 35 to 40 A | 34.8 to 36.4 A by the paper’s rule; 54.2 A by the array rule |
| Sun hours for 60 % surplus (520 Wp) | over 60 % | 6.15 h a day on average |
How we made the graphs
Every number and both charts come from scripts/blog-figures/off-grid-solar-ethiopia-tier-3-household-pv-battery-sizing.mjs in fibub’s public code. It calls solar() from src/lib/sci/batsolar.ts, the maths behind the battery solar sizing tool, for the array, panel count, battery bank, layout and controller current, and for the daily energy of a given array.
The daily demand, the 1.15 and 1.2 factors, the 85 % efficiency and depth of discharge, the 4.8 and 5.5 hours, 3 days, 12 V, 130 Wp modules and 250 Ah batteries all come from the paper’s text. Our mapping onto the tool’s fields: the demand factor goes in as an inverter efficiency of 1 ÷ 1.15 (87 %), the 85 % overall efficiency as 15 % system losses, and battery charge efficiency as 100 % (already inside the 85 %). The hours we gave each load band are our reading of the text.
How we test the maths
On every change to fibub, tests/sci.mjs runs tests/sci-tools/battery-solar-sizing.mjs, which checks the tool against an independent Python calculation of the same formulas:
- Five battery runtimes (loads in watts and in amps, Peukert exponents from 1 to 1.25), including 100 Ah at 12 V with a 60 W load at 90 % efficiency and half the capacity usable: 9.0 h simply and 8.81 h with Peukert’s k = 1.2.
- Three off-grid systems, including the tool’s example (1230 Wh/day at 4.5 sun hours, 25 % losses, 2 days at 50 %): an array of 449.9 W, a bank of 227.8 Ah at 24 V and a 41.7 A controller.
- New with this article: the Tier 3 home (1700 Wh at 87 % inverter efficiency, 15 % losses, 4.8 h, 130 Wp modules) must need 478.9 W and four modules, and at 100 % inverter efficiency its 3-day bank at 85 % must be 500 Ah, exactly two 250 Ah batteries.
Check it yourself
On the battery solar sizing page, in the Off-grid solar sizing card:
- Replace the text in Appliance, watts, hours per day, quantity with one line: Tier 3 home, 1700, 1, 1 (1700 W for 1 hour is the paper’s 1700 Wh a day as a single line; ignore the “draw up to” note this gives).
- Set Peak sun hours per day to 4.8, System losses (%) to 15, Inverter efficiency (%) to 87, Battery charge efficiency (%) to 100, Days of autonomy to 3 and Usable depth of discharge (%) to 85.
- Choose System voltage 12 V, Panel rating (W) 130, One battery: voltage (V) 12 and One battery: capacity (Ah) 250.
- Solar array needed reads 479 W, and the headline says 4 × 130 W panels, 3 × 12 V 250 Ah batteries (Battery bank 6900 Wh, 575 Ah).
- Now set Inverter efficiency (%) to 100: the bank falls to 6000 Wh, 500 Ah and the headline to 2 batteries, the paper’s 2 × 250 Ah. The array needed drops to 417 W, still four 130 W panels.
- Set Usable depth of discharge (%) to 50 to see what a lead-acid bank would need: 850 Ah, four batteries.
What researchers can use it for
- Audit a published sizing: put a paper’s demand, sun hours, efficiencies and autonomy through the battery solar sizing tool and see which of its numbers follow from which version of the method.
- Compare battery chemistries: change only the usable depth of discharge (50 % for lead-acid, 80 to 90 % for lithium iron phosphate) and read off the bank, then cost it over the years with the LCOE calculator.
- Pick the design sun hours: check what a panel really yields at the site and tilt with the solar PV yield tool before trusting a single worst-case number.
- Teach the method: students can rebuild a whole solar home system from a load list in a few minutes and see how each factor moves the answer.
- Grid-tied homes: for a home that also has the grid, simulate self-consumption hour by hour with home battery instead.
The fine print
- This is a recomputation from numbers in the paper’s text. We did not have its appliance table or its simulation files, and its own energy simulation (behind the 60 % surplus) is more detailed than a peak-sun-hours sum.
- How the 1.15 to 1.2 factor and the 85 % efficiency combine is our reading of the method’s wording; the tool’s fields are a close stand-in, not the paper’s spreadsheet.
- The controller rule in the tool (array watts ÷ volts × 1.25) suits MPPT controllers; for a PWM controller, use the modules’ short-circuit current × 1.25.
- A design for a real home needs local sun data, battery datasheets, cable and fuse sizing, and a qualified installer. Check the official source and local electrical rules.
Sources
- Lidate, A. J., Ancha, V. R., Worku, G. B., Behabtu, H. A., Yetayew, T. T. and Narra, S. (2026), Design and Tier-Based Analysis of an Off-Grid Solar PV System for Swarm Rural Electrification in Ethiopia, Energies 19(14): 3454, doi:10.3390/en19143454. Licence CC BY (Creative Commons Attribution), checked on the MDPI page, 2026-11-24. Values used here: Tier 3 design demand 1.7 kWh/day (Tier 3 range 1.43 to 1.68, Tier 2 0.79 to 0.93 kWh/day); total demand = demand × 1.15 to 1.2; overall efficiency 85 %; worst-case 4.8 peak sun hours and 5.5 h for the current; 3 days of autonomy; 85 % maximum depth of discharge; 12 V; 130, 150 or 170 Wp modules; result 400 Wp, four 130 Wp modules, 2 × 250 Ah and a 35 to 40 A controller; more than 60 % surplus; load bands 40 to 50 W overnight, about 80 W from 6 to 8 a.m., 50 to 60 W in the day and 110 to 120 W from 4 to 10 p.m.; annual irradiation 4.22 to 6.54 kWh/m²/day (models and satellite sets) and 7.30 (PVGIS).
- Off-grid sizing method (array = daily energy ÷ (peak sun hours × efficiency); bank = daily energy × days of autonomy ÷ depth of discharge; controller = array watts ÷ system volts × 1.25): common practice in solar design guides, as used in the fibub Battery solar sizing tool.