Open-source CubeSat solar panels on Ex-Alta 2: orbit power checked

Student-built, open-source solar panels flew on three CubeSats from the ISS. We rebuild Ex-Alta 2's panel power, eclipse share and orbit-average power.

Solar panels are one of the most expensive parts of a small satellite, and most CubeSat teams buy them ready-made. A 2024 conference paper from the University of Alberta’s student satellite group describes panels they designed, built and tested themselves, and is releasing the designs openly. The panels flew on three satellites deployed from the International Space Station in April 2023, including the 3U Ex-Alta 2. This is a preprint-style conference paper, not yet peer-reviewed in a journal. This article rebuilds Ex-Alta 2’s panel power, its time in Earth’s shadow and its orbit-average power with the cubeSat power budget tool, and shows why the answer moves through the year. To find the satellite’s real orbit, use the satellite tracker; to turn heights into orbital elements, the orbit elements tool.

The paper in brief

A CubeSat is built from 10 cm cubes: a 3U is three cubes long, about the size of a loaf of bread. Ex-Alta 2 carries five panels: three fixed to the body (on the zenith face, which points away from the Earth, and on the port and starboard sides) and two deployables, hinged wings that are folded over the sides at launch and open out level with the zenith face once in orbit. Each panel holds six high-efficiency triple-junction cells (three layers, each catching a different part of sunlight), 69 by 40 mm, wired in series.

The authors report a typical panel output of 14.4 V at 0.48 A at its best operating point, 5.2 to 7.4 W per panel in orbit, and an orbit-average power from a commercial simulator (STK) of 9.6 W ± 17 % with the wings open, but only 2.9 W if both wings had stayed stuck. The panels deliver power for at least 60 % of any orbit. Ex-Alta 2 uses 3.8 W in normal operation. The authors believe the panels worked as planned but give no measured on-orbit power.

Checked with the tools

Everything below is a recomputation with the tool’s maths from the paper’s stated cell size and layout. Three inputs are our assumptions: the cell efficiency (30.7 %, the maker’s figure), an ISS-like orbit (415 km, 51.64°), and a satellite that keeps its zenith face to the sky (nadir pointing). Losses are left out unless said.

Step 1: one panel. Six cells of 69 × 40 mm cover 165.6 cm². In full sunlight (1361 W/m²) at 30.7 % that is 6.92 W. The paper’s 14.4 V × 0.48 A is 6.91 W. The stated cell size and the maker’s efficiency agree with the measured panel to 0.1 %.

Step 2: time in the shadow. At 415 km an orbit takes 92.9 minutes. When the Sun lies in the orbit plane (a beta angle, the Sun’s height above the orbit plane, of 0°), the satellite spends 36.0 minutes, 38.8 % of the orbit, in Earth’s shadow, so it is in sunlight 61.2 % of the time at worst. That matches the paper’s “at least 60 % of any orbit”. Above a beta angle of 69.9° there is no eclipse at all.

Step 3: power against beta angle. Facing the Earth, the zenith-facing panels see the Sun best at orbit noon and not at all on the night side, while the side panels only see it when the Sun is well out of the orbit plane. With the wings open, the orbit-average power is 6.61 W at beta 0° and rises to 8.47 W at 74° (Figure 1). With both wings stuck (our reading: their cells face outwards over the sides) it falls to 2.20 W at beta 0°, below the satellite’s 3.8 W use, and only climbs to 7.26 W at high beta.

Ex-Alta 2: orbit-average power against beta angleEx-Alta 2: orbit-average power against beta angle02.557.510-50050Beta angle (°)Orbit-average power (W)nominal use 3.8 WWings openBoth wings stuckfibub.com
Figure 1. Orbit-average power from the CubeSat power budget tool's maths for Ex-Alta 2 pointing at the Earth at 415 km, against the beta angle (how far the Sun sits above the orbit plane). Cell efficiency 30.7 % and no other losses (our assumptions). The dashed line is the satellite's stated nominal use, 3.8 W.

Step 4: the first year. The ISS orbit’s beta angle swings between about −74.8° and +73.9° as the orbit turns and the seasons change. Day by day, the wings-open average stays between 6.64 and 8.71 W, a mean of 7.68 W (Figure 2). With both wings stuck the mean is 4.12 W, but on 147 days of the year it would fall below 3.8 W, so the satellite would need to cut its use.

Through the first year after deploymentThrough the first year after deployment02.557.5100100200300Days after 24 April 2023Orbit-average power (W)mean 7.7 WWings openBoth wings stuckfibub.com
Figure 2. The same power day by day for the first year, with the beta angle of an ISS-like orbit (51.64°, node drifting 5° a day; our assumption for the start). The dashed line is the year's mean with the wings open.

Step 5: comparing with the paper’s 9.6 W. Our year mean of 7.68 W sits just under the paper’s lower bound (9.6 − 17 % = 7.97 W). The average in sunlight only is 11.75 W, above it. The paper’s simulator likely includes things our simple model leaves out, such as sunlight reflected from the Earth (albedo) and its own attitude and orbit, so the two bracket it. For the stuck case, the paper’s 2.9 W lies between our two readings: 4.12 W if the stowed wings’ cells face outwards and 1.78 W if only the zenith panel works. Adding typical losses (panels at 60 °C and 90 % kept after converters, our assumption) lowers our wings-open mean to 6.36 W.

Check Paper Our tool result
Power of one panel 14.4 V × 0.48 A = 6.91 W 6.92 W (165.6 cm², 30.7 %)
Share of an orbit in sunlight at least 60 % 61.2 % at worst (415 km)
Orbit-average power, wings open 9.6 W ± 17 % 7.68 W year mean (6.64 to 8.71 W); 11.75 W in sunlight
Orbit-average power, wings stuck 2.9 W 1.78 to 4.12 W, depending on the stowed wings
Against the 3.8 W load not stated positive every day with wings open

How we made the graphs

The charts and every number come from scripts/blog-figures/ex-alta-2-cubesat-open-source-solar-panels-orbit-power.mjs in fibub’s public code. It calls panelPeak, eclipseFraction, period, betaStar and simulate from src/lib/sci/cubesatpower.ts, the maths behind the cubeSat power budget tool: a cylindrical Earth shadow, the Sun’s direction in a nadir-pointing body frame, and the power of each face summed step by step around the orbit.

The cell size, the panel layout, the 14.4 V and 0.48 A, the 3.8 W load and the paper’s simulated averages come from the paper. The 30.7 % efficiency, the 415 km and 51.64° orbit, the 5° a day drift of the orbit’s node, the starting position of the node and the way the stuck wings face are our assumptions. The beta angle through the year uses the standard formula from the Sun’s ecliptic longitude and the orbit’s node.

How we test the maths

On every change to fibub, tests/sci.mjs runs tests/sci-tools/cubesat-power-budget.mjs, which pins the tool against independent numpy calculations:

  • The share of the orbit in shadow at 400 km must be 0.3901 at beta 0° and 0.0461 at beta 70°, matching a brute-force shadow test at 2 million points around the orbit; above 70.2° it must be zero.
  • A nadir-pointing test satellite at 500 km and beta 20° must collect 25.805 Wh per orbit and reach a deepest discharge of 9.965 %, as a separate numpy simulation does.
  • New with this article: six 69 × 40 mm cells at 30.7 % must give 6.919 W; 415 km must be 61.2 % sunlit at beta 0°; and the five-panel Ex-Alta 2 layout at beta 20° with a 3.8 W load must average 7.67 W with a deepest discharge of 13.3 %.

Check it yourself

On the cubeSat power budget tool:

  1. In Orbit, type 415 in Altitude (km) and 20 in Beta angle (°).
  2. In Solar array, replace the Panels box with: Zenith, -Z, 165.6; Wing 1, -Z, 165.6; Wing 2, -Z, 165.6; Port, +Y, 165.6; Starboard, -Y, 165.6 (one panel per line). Keep Attitude on Nadir pointing.
  3. Set Cell efficiency (%) to 30.7, Packing to 100, Panel temperature (°C) to 28, Degradation per year (%) to 0 and Power kept after converters and wiring (%) to 100.
  4. In Loads, replace the box with Load, Power (W), Nominal on the first line and Whole satellite, 3.8, 100 on the second.
  5. The result reads Nominal: power positive, +6.00 Wh per orbit, deepest DoD 13.3 %, with Eclipse 35.3 min and Generation, orbit average 7.67 W (12.39 W average in sunlight).
  6. Delete the two wing lines and change Beta angle (°) to 0: the result turns to Nominal: dod over the limit, −2.47 Wh per orbit, deepest DoD 42.2 %, with 2.20 W of generation. A stuck pair of wings cannot carry the 3.8 W load in this season, as Figure 1 shows.

What researchers can use it for

  • Size a student CubeSat’s panels: try layouts, attitudes and beta angles before building, with the cubeSat power budget tool.
  • Check a vendor’s or a paper’s panel rating from cell size and efficiency in one line, as in Step 1.
  • Plan for a stuck deployable: see on which beta angles the satellite must go into a low-power mode.
  • Find the real beta angle of a flying satellite from its orbit with the satellite tracker, then read its power off the tool.
  • Teach why the same satellite makes more power in some weeks than others, and why “orbit average” and “average in sunlight” differ by more than a third.

The fine print

  • Our results come from a simple model: a cylindrical shadow, no Earth albedo, perfect nadir pointing and no shading between panels. The paper’s 9.6 W comes from a commercial simulator with its own settings, which the paper does not list in full.
  • The paper reports no measured on-orbit power, so nothing here checks the panels’ real performance.
  • The 30.7 % efficiency, the orbit and the stuck-wing geometry are our assumptions; the satellite’s orbit also sank over its life.
  • This is a conference paper on arXiv, not yet peer-reviewed in a journal.

Sources

  • Sorensen, N. J. and Halliwell, E. F. (2024), Open-Source CubeSat Solar Panels: Design, Assembly, Testing, and On-Orbit Demonstration, arXiv:2407.19356 (presented at the 2024 SmallSat Conference, Logan, Utah), doi:10.48550/arXiv.2407.19356. Licence CC BY 4.0, checked on the arXiv page, 2026-11-24. Conference paper, not peer-reviewed in a journal. Values used here: Ex-Alta 2 is a 3U CubeSat facing the Earth; five panels (body zenith, port and starboard, and two deployables stowed over port and starboard that open parallel to the zenith face); six Spectrolab XTJ Prime cells of 69 × 40 mm per panel in series; panel maximum power point 14.4 V and 0.48 A; orbital power per panel 5.2 to 7.4 W (typical 6.2); simulated (STK) orbit-average power 9.6 W ± 17 % nominal and 2.9 W with both deployables stuck; power for at least 60 % of any orbit; satellite use 3.8 W nominal and 6.1 W in full-function mode; deployed from the ISS on 24 April 2023.
  • Cell efficiency of 30.7 % (beginning of life, AM0): Spectrolab XTJ Prime data sheet. Our assumption that the flight cells match it.
  • ISS orbit (about 415 km, 51.64°, node drifting about 5° a day): standard published values; our assumption for Ex-Alta 2's first year.

If you are an author or publisher and want a credit or a passage changed or removed, tell us and we will act quickly.

Tools in this article