Aria's 350 m argon column: how many stages does isotope distillation need?

To remove argon-39 from argon, the Aria column must separate isotopes whose volatility differs by 0.13 %. We recompute its stage counts with the Fenske equation of the McCabe-Thiele tool.

Argon from the air contains a trace of radioactive argon-39, which would swamp a sensitive dark-matter detector with false signals. Argon from deep underground has far less of it, but it is scarce. The Aria project therefore plans to clean ordinary argon by distillation: boil it at about 90 K in a column 350 m tall and let the lighter isotope argon-39 drift one way and argon-40 the other. The catch is that the two isotopes have almost the same boiling behaviour, so a huge number of “stages” is needed. This article recomputes the column’s stage counts with the same maths as the McCabe-Thiele calculator. The vapour pressures behind the volatility are the job of the vapour pressure, and the flows of the product streams are a mass balance task.

The paper in brief

A distillation stage is one round of boiling and condensing in which the vapour ends up slightly richer in the more volatile component than the liquid it left. The relative volatility α is how much richer: the ratio of the two components’ vapour pressures. For argon-39 against argon-40 the paper gives the natural logarithm of α as about 1.333 thousandths, with an uncertainty of 0.036 thousandths, at the column’s mean temperature of 89.5 K. So α is only about 1.0013: each stage changes the isotope ratio by a little over a tenth of a percent.

To make up for that, the column is packed with structured metal gauze. The authors quote a height equivalent to a theoretical stage (HETP) of 10 cm, meaning every 10 cm of packing does the work of one ideal stage. They state that the full column holds 2870 theoretical stages, about 287 m of active packing inside the 350 m shaft. They also state an illustrative number: at total reflux (all the condensed vapour returned to the column, the best case for separation) a ten-fold separation needs at least 1727 stages. The design goal is a ten-fold reduction of argon-39 in each pass.

Checked with the tools

The tool’s Fenske equation gives the fewest stages at total reflux for a constant relative volatility:

Nmin = ln[ (xD / (1 − xD)) ÷ (xB / (1 − xB)) ] ÷ ln α

Here xD and xB are the light-component fractions at the top and bottom. The bracket is the separation factor S: the ratio of the two “odds”. For isotopes the exact composition does not matter, only S does, so we take (our assumption) xD = 0.5 and xB = 1/11 for S = 10.

Quantity Paper says Tool gives
α from ln α = 1.333 × 10⁻³ about 1.0013 1.001334
Nmin for S = 10 1727 1727.4 (stepped on the McCabe-Thiele diagram: 1728)
Nmin range for the ± 0.036 × 10⁻³ uncertainty not stated 1682 to 1775
Separation reached by 2870 stages at total reflux not stated S = 45.9 (41.4 to 50.9 over the uncertainty)
Packing height for S = 10 at HETP 0.10 m not stated 172.7 m

So the paper’s 1727 is exactly the Fenske number, and the stepped count on the McCabe-Thiele diagram agrees to one stage. The new information is the second chart: because ln S = N ln α, the separation grows exponentially with height. The 287 m of packing at total reflux reaches a factor of about 46, comfortably above the factor of 10 that the design asks per pass, which leaves room for the finite reflux, losses and real-world flow limits. A factor of 100 would need about 3455 stages, or about 345 m of packing, which is close to the whole 350 m shaft.

Fenske minimum stages against separation factorFenske minimum stages against separation factor0100020003000020406080Separation factor S (odds ratio top : bottom)Minimum theoretical stages2870 stages built+1σ in ln α (fewer)ln α = 1.333e-3-1σ (more)paper: 1727 at S = 10fibub.com
Figure 1. Fenske minimum number of stages for argon-39 against argon-40, from the stated ln α (solid) and its one-sigma band (dashed). The dot is the paper's own 1727-stage example; the dashed horizontal line is the 2870 stages of the full column.
Separation reached against packed heightSeparation reached against packed height204060801000100200300Packed height (m, at HETP = 0.10 m)Separation factor S at total reflux287 m-1σln α = 1.333e-3+1σfibub.com
Figure 2. The separation a column of this packing reaches at total reflux, from S = α to the power N with N = height ÷ 0.10 m. The full 287 m of packing gives a factor of about 46.

One uncertainty matters more than the rest: the volatility. The one-sigma band on ln α moves the 1727 stages by about ± 50 stages and the reachable separation between 41 and 51, so the column’s headroom over the design goal (a factor of at least 4) survives it.

How we made the graphs

The script scripts/blog-figures/aria-cryogenic-distillation-argon-39-fenske-minimum-stages.mjs imports alphaEq, fenske and stepStages from src/lib/sci/mccabe.ts, the maths behind the McCabe-Thiele calculator. Inputs from the paper’s text: ln α = (1.333 ± 0.036) × 10⁻³, 2870 stages, HETP 10 cm. Our assumptions: xD = 0.5 with xB = 1/(1 + S) to set a separation factor S, and a feed of xF = 0.2 for the stepping (total reflux does not depend on it). Figure 1 is fenske() over S; Figure 2 is S = exp(ln α × height ÷ HETP). The stepped count of 1728 comes from stepStages at total reflux with a limit of 6000 stages.

How we test the maths

The checks in tests/sci-tools/mccabe-thiele-calculator.mjs run with node tests/sci.mjs on every change. They pin Fenske against its closed form for an exact case (α = 2, S = 1 gives N = 0, S = 4 at α = 2 gives N = 2), the stepped total-reflux count to the Fenske value within one stage, and, new with this article, the isotope case: ln α = 1.333 × 10⁻³ and S = 10 give 1727.4 stages, 2870 stages give S = 45.87, and stepping with α = 1.0134192 and S = 10 gives 173 stages, one more than Fenske’s 172.74.

Check it yourself

Writing this article turned up a stage cap of 300 in the page, which refused every isotope column; it is 5,000 now, so the real α goes straight in. The scaled version below is still the quickest thing to read, because it uses an α with ten times the log-volatility and so needs one tenth of the stages:

  1. Open the McCabe-Thiele calculator. Under Equilibrium from, keep “A constant relative volatility” and type 1.01342 in Relative volatility α.
  2. Set Feed, light fraction xF to 0.2, Distillate xD to 0.5 and Bottoms xB to 0.090909.
  3. Under Reflux choose “Total reflux (minimum stages)”.
  4. You should read “173 stages at total reflux (minimum: 172.73)”, and the Minimum stages (total reflux) fact shows 172.73 from the Fenske equation.
  5. Multiply 172.73 by 10: that is 1727, the paper’s number for the real isotope pair, because ln α is ten times smaller in the real case.
  6. Now type the real 1.0013339 in Relative volatility α, leaving the fractions as they are, and the page steps the full column: 1,728 stages, minimum 1,727.37.

What researchers can use it for

  • Sizing a packed column for any difficult separation (isotopes, close-boiling pairs) from a measured α and an HETP, before running a detailed simulation.
  • Seeing how a small error in α propagates into the required height, as the shaded band in Figure 1 does.
  • Teaching why separation factors multiply stage by stage, and why α close to 1 makes columns tall.
  • Cross-checking a published stage count against the Fenske limit: a column with fewer stages than Nmin cannot reach the stated purity.
  • Estimating how α depends on temperature by looking up the two vapour pressures in the vapour pressure and taking their ratio.

The fine print

This is a recomputation from numbers stated in the paper’s text; nothing was measured by us. Fenske’s equation assumes a constant α and total reflux, so it gives a lower bound; a real column run with finite reflux, feed and withdrawals needs more stages. The paper’s own design work (column hydraulics, packing wetting, heat duty, the actual argon-39 depletion) is far richer than this check, and its tables of results were not readable for this article. The split into xD = 0.5 and xB = 1/11 is our choice to fix a separation factor of 10; the isotope result depends only on that factor. For anything that matters, read the paper and consult the collaboration’s published results.

Sources

  • Agnes, P. et al. (DarkSide-20k Collaboration; 309 named authors, first ten: Agnes P, Albergo S, Albuquerque IFM, Alexander T, Alici A, Alton AK, Amaudruz P, Arba M, Arpaia P, Arcelli S), Separating 39Ar from 40Ar by cryogenic distillation with Aria for dark-matter searches, European Physical Journal C 81: 359 (2021), doi:10.1140/epjc/s10052-021-09121-9. Licence CC BY 4.0, taken from the Crossref record (the Springer page says only 'open access, 2021 The Author(s)'); the Crossref record has no retraction or correction notice; checked 2026-11-24. Values used here, all stated in the running text: ln α(39Ar/40Ar) = (1.333 ± 0.036) × 10^-3 at a mean column temperature of 89.5 K (top 87.8 K, bottom 90.9 K); N = 2870 theoretical stages; HETP 10 cm; 2.56 m packing sections, four per module, 28 central modules; total height 350 m; a minimum of 1727 stages for a separation factor of 10 at total reflux; design goal a ten-fold reduction of argon-39 per pass.
  • Fenske (1932) minimum stages at total reflux, N = ln[(xD/(1-xD))/(xB/(1-xB))] / ln α: standard chemical engineering, written from the equation.
  • Companion paper (not used for numbers): Measurement of isotopic separation of argon with the prototype of the cryogenic distillation plant Aria for dark matter searches, Eur. Phys. J. C 83: 453 (2023), doi:10.1140/epjc/s10052-023-11430-0; its tables of measured separations were not readable, so nothing from it is recomputed.

If you are an author or publisher and want a credit or a passage changed or removed, tell us and we will act quickly.

Tools in this article